PLC在恒壓供水模糊控制系統(tǒng)中的應用
時間:2008-05-07 15:02:00來源:yangliu
導語:?介紹了基于PLC與變頻調(diào)速技術(shù)的供水泵組的控制系統(tǒng)設計。包括系統(tǒng)的組成、工作原理、模糊控制策略的設計思想
摘要:介紹了基于PLC與變頻調(diào)速技術(shù)的供水泵組的控制系統(tǒng)設計。包括系統(tǒng)的組成、工作原理、模糊控制策略的設計思想,較好地解決了傳統(tǒng)PID控制中穩(wěn)定性差、參數(shù)調(diào)整困難的問題,提高了供水質(zhì)量,節(jié)能效果明顯,具有應用推廣價值
關(guān)鍵詞:PLC;變頻器;模糊控制;恒壓供水
Abstract:The design of fuzzy control system for water supply pumps is introduced,The system is based on technologies of PLC and inverter.Th e structure,working principle, design of fuzzy controller were included, it can settle the traditional PID control problems such as bad stability,dificult to modulate parameter.It improve the quali~ of water supplying,and there is obvious efect of energy saving and certain of practicing and popularizing value in it.
Key words:PLC ,Inverter ,F(xiàn)uzzy control,W ater supplying
引言
隨著變頻調(diào)速技術(shù)的發(fā)展和人們對生活飲用水品質(zhì)要求的不斷提高,變頻恒壓供水系統(tǒng)已逐漸取代原有的恒速泵組切換加壓供水、調(diào)節(jié)閥門供水、高位水塔供水等供水系統(tǒng),廣泛應用于多層住宅小區(qū)和高層建筑生活及消防供水系統(tǒng)。然而,運用單片機或PLC與變頻器結(jié)合為核心的供水控制系統(tǒng),往往會繼續(xù)使用原有系統(tǒng)的部分舊設備(如水泵),在對原有供水系統(tǒng)進行變頻改造的實踐中,往往會出現(xiàn)一些在理論上意想不到的問題。如單片機在硬軟件設計、程序調(diào)試難度較大,系統(tǒng)抗干擾性能較差;而采用帶有模人膜出的PLC,設備成本高,PID算法編程難度大,現(xiàn)場調(diào)試要求調(diào)試人員素質(zhì)比較高。因此對于難以確定數(shù)學模型且控制精度要求不太高的系統(tǒng)。將PLC與交流變頻調(diào)速技術(shù)相結(jié)合,采用實用有效的模糊控制算法,開發(fā)更易實現(xiàn)供水參數(shù)的調(diào)節(jié)、可靠性高、控制性能好的恒壓供水模糊控制系統(tǒng)具有很高的實用價值。
[b]1 變頻恒壓供水控制系統(tǒng)的設計
1.1系統(tǒng)設計方案分析[/b]
目前國內(nèi)多數(shù)供水企業(yè)水泵類機械的典型電氣傳動仍是用鼠籠式異步電動機驅(qū)動,因為它具有結(jié)構(gòu)簡單、運行可靠、維修方便、價格低廉等優(yōu)點。但其本身調(diào)速較難,故常為恒速運轉(zhuǎn);當需要調(diào)節(jié)流量時,則采用調(diào)節(jié)閥門的方法,這至少浪費20%的能源。統(tǒng)計表明,我國每年水泵消耗的電能約占電能總耗的20%以上,而電耗又占水費成本的6O%以上。
[b][align=center]詳細內(nèi)容請點擊:
PLC在恒壓供水模糊控制系統(tǒng)中的應用[/align][/b]