Abstract:In recent years, with the large number of solar photovoltaic power plants establishing and grid connection generation at home and abroad , As the key equipment in PV power generation, photovoltaic grid-connected inverter has broad market prospect. The introduction in this paper focus on the application of WEINVIEW touch screen in photovoltaic grid-connected inverter. In this system, touch screen communicates with the microcontroller, and completes related data acquisition, information saving, alarm information loginning, and shows operating parameters and real-time status of inverter on the touch screen , Remote communication with the host computer through the RS485 or the Ethernet, At last to achieve real-time monitoring and deploy of the entire grid station.
關鍵字:光伏 逆變器 觸摸屏 DSP
Keywords: Photovoltaic Inverter Touch screen DSP
一:引言
隨著全球氣候變暖,傳統(tǒng)的燃料資源日趨枯竭,世界各國都把目光投向了可再生能源,希望可再生能源改變?nèi)祟惖哪茉唇Y構,維持長遠的可持續(xù)發(fā)展。在可再生能源中,太陽能以其獨有的優(yōu)勢而成為人們關注的焦點。太陽能是取之不盡、用之不竭、無污染的綠色能源。世界各國都在投入巨資建設大規(guī)模的太陽能發(fā)電站。我國在光伏研究和產(chǎn)業(yè)方面也取得了較快的進展,2006年1月1日實施的《可再生能源法》,標志著太陽能發(fā)電已納入我國的能源發(fā)展規(guī)劃之中。根據(jù)2007年9月發(fā)布的《可再生能源中長期發(fā)展規(guī)劃》,2020年,我國太陽能發(fā)電設備累計裝機容量將達到2000MW 。
太陽能光伏并網(wǎng)逆變器是整個光伏發(fā)電系統(tǒng)中最為關鍵的設備之一,它是把太陽能電池板產(chǎn)生的直流電能轉換為交流電能的設備,運行過程中需要多個參數(shù)進行監(jiān)測、計算、顯示、記錄、保存、報警等處理,需要和上位計算機、逆變控制器進行通訊,實現(xiàn)數(shù)據(jù)交換。本文主要講述WEINVIEW觸摸屏在太陽能光伏并網(wǎng)逆變器中的應用。
二:系統(tǒng)原理和方案設計
太陽能光伏并網(wǎng)逆變器是把太陽能電池板通過光伏效應產(chǎn)生的直流電能進行逆變,轉換成同電網(wǎng)同頻率、同相位的交流電,接入電網(wǎng)對外進行輸電。逆變器運行中要把測量的實時參數(shù)送給觸摸屏,進行顯示、記錄等操作,也可和上位機通訊進行遠程監(jiān)控功能。系統(tǒng)原理圖如下圖所示:
三:WEINVIEW畫面設計要求
本系統(tǒng)采用WEINVIEW MT8010IV2型號觸摸屏,高品質(zhì)10”寬屏設計,LED背光模組,采用400MHz RISC CPU,使運行速度更快,內(nèi)置電源隔離保護器,提高了產(chǎn)品的抗干擾能力,適應復雜環(huán)境下運行。多種標準的通訊接口和網(wǎng)絡協(xié)議,方便用戶使用。大容量的數(shù)據(jù)存儲功能,外接USB閃存和SD卡存儲資料,滿足逆變器運行過程中產(chǎn)生的海量數(shù)據(jù)信息。
1,觸摸屏主界面設計
主界面顯示逆變器運行的各種運行參數(shù):PV電壓、PV電流、A、B、C三項交流電壓和電流、功率因數(shù)、電網(wǎng)頻率、輸出功率、日發(fā)電量、總發(fā)電量、CO2減排量等,逆變器運行狀態(tài)指示,實時時間,以及其他操作菜單。下圖分別是主界面的中英文顯示菜單。
2,功率曲線顯示功能設計
逆變器運行中實時功率是一個非常重要的參數(shù),功率曲線圖反映逆變器運行的歷史運行情況和趨勢。逆變器功率曲線顯示由三條宏指令完成:
A:逆變器運行的實時功率計算
B:實時功率的RW_A保存
C:功率曲線顯示
實時功率計算宏指令如下:
macro_command main()
short i,v
int pa,pb,pc
GetData(v, "Local HMI", LW, 2, 1) //A相電壓
GetData(i, "Local HMI", LW, 3, 1) //A相電流
pa=v
pa=pa*i //相乘
GetData(v,"Local HMI", LW, 4, 1) //B相電壓
GetData(i,"Local HMI", LW, 5, 1) //B相電流
pb=v
pb=pb*i //相乘
GetData(v, "Local HMI", LW, 6, 1) //C相電壓
GetData(i, "Local HMI", LW, 7, 1) //C相電流
pc=v
pc=pc*i //相乘
pc=pa+pb+pc //A相B相C相功率之和
SetData(pc, "Local HMI", LW, 300, 1)//存儲在LW300中
end macro_command
功率計算宏指令1秒鐘循環(huán)執(zhí)行一次,把三相輸出功率之和保存在LW300單元中。
功率存儲宏指令如下:
macro_command main()
short day,hour,minute
int add,x
GetData(minute, "Local HMI", LW, 9018, 1) //讀取分
GetData(hour, "Local HMI", LW, 9019, 1) //讀取時
GetData(day, "Local HMI", LW, 9020, 1) //讀取日
add=day*1440+hour*60+minute //當前功率保存地址計算
GetData(x, "Local HMI", LW, 300, 1) //實時功率
SetData(x, "Local HMI", RW_A, add, 1) //保存在RW_A中
end macro_command
功率存儲宏指令1分鐘循環(huán)執(zhí)行一次,根據(jù)當前時間計算出功率存儲的地址,把當前功率值保存在此地址中。實時保存地址=日*1440+時*60+分。每分鐘保存一次,功率數(shù)據(jù)占一個單元(功率數(shù)據(jù)保存是從0時開始的全天數(shù)據(jù))。
XY曲線顯示配置方式如下:
四:觸摸屏通訊設計
光伏并網(wǎng)逆變器運行時的實時參數(shù)、狀態(tài)等要及時傳輸?shù)接|摸屏上進行計算、顯示、記錄、報警等,通訊設計采用RS232,比特率為9600,因為光伏逆變器主控制器采用TI公司TMS320F2812 數(shù)字處理器,觸摸屏采用MODBUS RTU (Adjustable)通訊協(xié)議,系統(tǒng)參數(shù)設置如下。
觸摸屏獲取逆變器數(shù)據(jù)采用定時數(shù)據(jù)傳輸模塊,設置如下,1秒定時進行數(shù)據(jù)讀取逆變器單元0開始的12個單元,逆變器實時運行數(shù)據(jù)保存在LW100連續(xù)的12個地址單元中。
光伏并網(wǎng)逆變器在需要和上位機進行并網(wǎng)發(fā)電監(jiān)控時,采用458總線通訊,主從方式,觸摸屏作為MODBUS Server設備。根據(jù)設置的站號進行區(qū)分。當上位機發(fā)出讀取逆變器運行數(shù)據(jù)命令,符合觸摸屏站號時,觸摸屏返回相應單元的內(nèi)容。完成數(shù)據(jù)傳輸,實現(xiàn)光伏電站的監(jiān)控功能。系統(tǒng)參數(shù)設置
五:結束語
本系統(tǒng)采用WEINVIEW MT8100I觸摸顯示屏,實現(xiàn)了和DSP數(shù)字信號處理器的實時通訊。圖文并茂的顯示了并網(wǎng)逆變器運行的各個參數(shù)和狀態(tài),曲線坐標顯示了逆變器的功率參數(shù)和其趨勢效果圖。大容量的數(shù)據(jù)存儲功能,保存了逆變器詳細的歷史運行數(shù)據(jù)。靈活、多樣的通訊接口方便實現(xiàn)光伏并網(wǎng)電站的監(jiān)控。觸摸屏可靠、穩(wěn)定的運行,方便、靈活的操作,大大提高并網(wǎng)逆變器產(chǎn)品的市場競爭力,取得了良好的社會效益和經(jīng)濟效益。