[abstract] the article is presentation high voltage convertor device use in Baijing YanHua supply water workshop, it is untie so make of big water pump from little flux the earth is surface water source pump water appear empty of difficult problem by convertor device can being deep measurement speed stepless modulation of excellence。Uitilize little flux the earth surface water the same time economize more electric energy, take out resource and economic of dual benefit.
[key word] high voltage convertor device adjustive speed run economize energy
1、 引言:
在泵站供水系統(tǒng)中,常常是多泵供應(yīng)多個(gè)用戶,同時(shí)內(nèi)部管路進(jìn)行聯(lián)網(wǎng),能做到互為備用。在設(shè)計(jì)初期多個(gè)用戶的用量是基本一致的。但經(jīng)常有個(gè)別終端的用戶常會(huì)由于工況改變,工藝調(diào)整,供應(yīng)面積變化等原因,其供水量會(huì)小于原設(shè)計(jì)的容量,這時(shí)就出現(xiàn)了用大泵往出輸送小水量的情況。
北京燕化公司動(dòng)力事業(yè)部一供水車間的其中一路供水用戶的用水量較小,其總需求量不到水泵額定容量的三分之一。運(yùn)行時(shí)檔板開度很低,在運(yùn)行時(shí)泵壓較高,不但是電能浪費(fèi)較大。同時(shí)用檔板調(diào)節(jié)時(shí),由于其開度與流量的非線性特性,往往一個(gè)很小角度的調(diào)節(jié),其流量就發(fā)生很大的變化。
在北京燕化公司動(dòng)力事業(yè)部一供水車間附近,有一個(gè)小流量水渠,其地表流量與用量較小的用戶終端的使用量相近。在2004年,北京水務(wù)局從北京水資源的充分利用出發(fā),要求北京燕化公司將這個(gè)小流量地表水利用上,以優(yōu)化水網(wǎng)的資源調(diào)配。但是實(shí)際的供水調(diào)配時(shí),由于其小流量地表水流量與用量較小的用戶終端的使用量相近,而泵的容量較大,用檔板調(diào)節(jié)時(shí),不是供水量不足,就是將小流量地表水抽干,無法對(duì)其進(jìn)行利用。
為充分利用珍貴的水資源和電力資源,北京燕化公司動(dòng)力事業(yè)部一供水車間對(duì)3號(hào)泵進(jìn)行調(diào)速改造,通過高壓變頻器能對(duì)轉(zhuǎn)速無級(jí)精密調(diào)節(jié)的功能,使大流的量3號(hào)泵能順利抽取小流量的地表水渠中的水滿足用戶終端要求而不出現(xiàn)抽空現(xiàn)象。
2、 燕化公司一供水車間3號(hào)泵參數(shù)與改造方案簡介:
(1)、燕化公司一供水車間3號(hào)取水泵參數(shù):
名稱:離心式清水泵 型號(hào):24SA—10A
揚(yáng)程:39m 流量:2700 m3/h
允許吸上真空高度:4.8 m 轉(zhuǎn)速:730 r/min
功率:319KW 配用功率:360KW
生產(chǎn)日期:1975年5月 重量:4100Kg
生產(chǎn)廠家:長沙水泵廠
(2)、3號(hào)取水泵配套電動(dòng)機(jī)參數(shù):
名稱:異步電動(dòng)機(jī) 型號(hào):JS158-8
額定功率:380KW 額定電壓:6000V
額定電流:47A 環(huán)境溫度:35℃
轉(zhuǎn)速:740 r/min 絕緣等級(jí):A
接法:星 重量:4100 Kg
技術(shù)條件:OAG.510.004 序號(hào):750259
生產(chǎn)日期:1975年6月
生產(chǎn)廠家:湘潭電機(jī)廠
(3)、北京燕化公司動(dòng)力事業(yè)部一供水車間3號(hào)泵取水網(wǎng)簡介:
在北京的頤和園水系中,有一路從燕山下來的小流量天然水道,其流量較小,平均僅在1000 m3/h左右,但是其水質(zhì)較好,在匯入總水系前,其能作為優(yōu)質(zhì)水源而直接利用。
北京燕化公司動(dòng)力事業(yè)部一供水車間3號(hào)泵的進(jìn)口管道經(jīng)過多管路的組合,即可以從主干渠中取水,宜可從小流量地表水渠取水,其形式如圖所示:
圖1 3號(hào)泵取水系統(tǒng)
在圖中,用水終端的用水為880m3/h,小流量地表水的流量約為1000 m3/h。在用3號(hào)泵進(jìn)行小流量地表水取水的測(cè)試中,用出口閥調(diào)節(jié)出水的流量,由于閥調(diào)節(jié)流量的精度較低,同時(shí)從取水到時(shí)供水的管路都較長,在達(dá)到時(shí)終端用水要求時(shí),其輸出流量多出用水終端較多。隨著小流量地表水的早晚流量的變化,出現(xiàn)了將小流量地表水抽干的現(xiàn)象。經(jīng)過多次調(diào)節(jié),由于精度不夠,不時(shí)出現(xiàn)用水終端供水不足,再就是小流量地表水抽干,并出現(xiàn)了幾次水泵打空,險(xiǎn)些出現(xiàn)水錘事故。
在這種情況下,只好放棄對(duì)小流量地表水的應(yīng)用。這樣不但是小流量的水資源白白的浪費(fèi),而且由于從主干渠取水的管道比從小流量地表水要長出近一倍多,又浪費(fèi)了大量的電能,并占用了大量的管道資源。
(4)、北京燕化公司動(dòng)力事業(yè)部一供水車間3號(hào)泵調(diào)速改造方案:
為充分利用水源資和節(jié)能增效,通過大量的分析與調(diào)查,確定利用高壓變頻器對(duì)電機(jī)速度調(diào)節(jié)精度高,輸出力矩穩(wěn)定的特點(diǎn),采用檔板全開運(yùn)行,在低轉(zhuǎn)速下能實(shí)現(xiàn)小流量,低泵壓的精細(xì)流量輸出。故北京燕化公司動(dòng)力事業(yè)部確定用變頻調(diào)速的方案可以使額定流量為2700 m3/h的離心水泵穩(wěn)定輸出880m3/h的水量,達(dá)到利用小流量地表水為小水量用戶供水的目標(biāo)。
北京市水務(wù)局于2004年12月份投資采用哈爾濱九洲電氣股份有限公司生產(chǎn)的高壓變頻調(diào)速裝置對(duì)3號(hào)泵進(jìn)行改造。
1、 變頻調(diào)速節(jié)能的原理分析:
(1)、離心泵負(fù)載的相似理論
離心泵的流量,運(yùn)行壓力,吸收軸功率這三個(gè)基本參數(shù)與轉(zhuǎn)速間的運(yùn)算公司極其復(fù)雜,同時(shí)離心泵類負(fù)荷隨環(huán)境變化參數(shù)也隨之變化,在工程一般根據(jù)離心泵的運(yùn)行曲線,進(jìn)行大致的參數(shù)運(yùn)算,稱之為離心泵類負(fù)載的相似理論:
Q / Q0 = n / n0
H / H0 = ( n / n0 )2( ρ / ρ0 )
N / N0 = ( n / n0 )3( ρ / ρ0 )
式中: Q -- 離心泵流量 H -- 離心泵全壓 n -- 離心泵轉(zhuǎn)速 ρ-- 介質(zhì)密度 N -- 軸功率
離心泵流量Q與電機(jī)轉(zhuǎn)速n成正比。(Q∝n)
離心泵壓力H與電機(jī)轉(zhuǎn)速n的平方成正比。(H∝n2)
離心泵軸功率N與電機(jī)轉(zhuǎn)速n的立方成正比。(N∝n3)
(2)、離心泵在額定工況下運(yùn)行的特性曲線
圖2 離心泵特性曲線(β=90º)
⑴H—Q曲線:當(dāng)轉(zhuǎn)速為恒定時(shí),表示離心泵壓力與流量間的關(guān)系特性。
⑵N—Q曲線:當(dāng)轉(zhuǎn)速為恒定時(shí),表示離心泵軸功率與流量間的關(guān)系特性。
⑶η—Q曲線:當(dāng)轉(zhuǎn)速為恒定時(shí),表示離心泵的效率特性。
從中可以看出,離心泵的軸功率和離心泵壓力相交處即為效率最高點(diǎn)。
(3)、電動(dòng)機(jī)容量的計(jì)算:
其中:
P ——離心泵電動(dòng)機(jī)所需的輸出軸功率(kW);
Q ——離心泵流量(m3/s);
H ——離心泵壓力(kg/m2);
——傳動(dòng)裝置的效率;直接傳動(dòng)為1.0,皮帶傳動(dòng)為0.9~0.98,齒輪傳動(dòng)為0.96~0.98。
——離心泵的效率;
102 ——由kg•m/s變換為kW的單位變換系數(shù);
(4)、通過改變離心泵的管網(wǎng)特性曲線來實(shí)現(xiàn)對(duì)離心泵的介質(zhì)流量的調(diào)節(jié)
通常的辦法是通過調(diào)節(jié)擋板的開關(guān)程度來實(shí)現(xiàn)的,
圖3、不同管網(wǎng)的特性曲線離心泵流量的特性曲線
如圖所示。
離心泵檔板開度一定時(shí),離心泵在管網(wǎng)特性曲線R1工作時(shí),工況點(diǎn)為M1。
離心泵擋板關(guān)小,管網(wǎng)特性曲線變?yōu)镽2,工況點(diǎn)移至M2。
離心泵擋板再關(guān)小,管網(wǎng)特性曲線變?yōu)镽3,工況點(diǎn)移至M3。
從上面的曲線分析,通過調(diào)節(jié)離心泵檔板的開度,管網(wǎng)的特性參數(shù)將發(fā)生改變,輸出流量發(fā)生變化,這樣就達(dá)到了在定速運(yùn)行時(shí)調(diào)節(jié)離心泵輸出流量的目標(biāo)。
在調(diào)節(jié)離心泵流量的過程中,離心泵的性能曲線(H—Q曲線)不變,工況點(diǎn)沿著離心泵的性能曲線(H—Q曲線)由M1移到M2,特性曲線由R1變?yōu)镽2,風(fēng)機(jī)輸出流量由Q1變?yōu)镼2。這時(shí)離心泵隨著輸出流量的減少,離心泵的壓力相應(yīng)上升。
這種調(diào)節(jié)流量方法簡單,操作容易。但是在流量減少的同時(shí),離心泵壓力同時(shí)上升,而經(jīng)過檔板后的運(yùn)行壓力卻又很低,這樣使大量的軸功率消耗在離心泵體的內(nèi)部壓力的無效損耗上,不但浪費(fèi)了大量的能源,同時(shí)由于泵體內(nèi)壓力較大,其機(jī)械結(jié)構(gòu)的損害也較大。
(5)、通過改變離心泵的轉(zhuǎn)速來實(shí)現(xiàn)對(duì)離心泵的流量調(diào)節(jié)
在離心泵的管網(wǎng)特性不變情況下,改變離心泵的轉(zhuǎn)速,使離心泵的特性曲線(H—Q曲線)平行移動(dòng),工況點(diǎn)將沿著管網(wǎng)特性曲線移動(dòng),達(dá)到調(diào)節(jié)離心泵流量的目的。
圖4、離心泵在不同轉(zhuǎn)速時(shí)的特性曲線
當(dāng)離心泵轉(zhuǎn)速為n1時(shí),離心泵的壓力-流量曲線與管網(wǎng)特性曲線R相交于M1點(diǎn)。
當(dāng)離心泵轉(zhuǎn)速為n2時(shí),離心泵的壓力-流量曲線與管網(wǎng)特性曲線R相交于M2點(diǎn)。
當(dāng)離心泵轉(zhuǎn)速降低,流量降低的同時(shí),離心泵的壓力也同時(shí)隨之降低,這樣,在調(diào)低流量的同時(shí),離心泵內(nèi)部壓力也隨之下降,具有極好的節(jié)電效果。
這種方法不必對(duì)離心泵本身進(jìn)行改造,轉(zhuǎn)速由外部調(diào)節(jié),離心泵檔板可處于最大點(diǎn)保持不變,并能實(shí)現(xiàn)無極線性調(diào)節(jié)流量。
(6)、采用改變離心泵轉(zhuǎn)速調(diào)節(jié)流量與采用改變離心泵檔板調(diào)節(jié)流量消耗功率的差值
采用改變離心泵轉(zhuǎn)速和改變管網(wǎng)特性進(jìn)行離心泵輸出流量的調(diào)節(jié),在調(diào)節(jié)相同流量的時(shí)候,其離心泵的特性曲線(H—Q曲線)變化不同,二種調(diào)節(jié)方法的運(yùn)行工況點(diǎn)也不同其運(yùn)行的對(duì)比圖如下
圖5、離心泵轉(zhuǎn)速調(diào)節(jié)與檔板調(diào)節(jié)的特性曲線對(duì)比
●在額定流量Q1時(shí):
離心泵檔板為額定開度,其管網(wǎng)特性曲線為R1,離心泵轉(zhuǎn)速為額定轉(zhuǎn)速,其特性曲線為n1,此時(shí)離心泵處于額定出力的狀態(tài),轉(zhuǎn)速調(diào)節(jié)和檔板調(diào)節(jié)的工況點(diǎn)重合,處于M1點(diǎn),此時(shí)兩種調(diào)節(jié)方式的消耗軸功率是相同的。
●在運(yùn)行中需輸出流量Q2時(shí)調(diào)速運(yùn)行離心泵消耗軸功率:
調(diào)節(jié)離心泵轉(zhuǎn)速將流量調(diào)為Q2,這時(shí)離心泵的特性曲線(H—Q曲線)平行下移,工況點(diǎn)處于M2點(diǎn),離心泵壓力變?yōu)镠2。其消耗的軸功率為 :
●在運(yùn)行中需輸出流量Q2用檔板調(diào)節(jié)流量時(shí)離心泵消耗軸功率:
調(diào)節(jié)離心泵檔板改變管網(wǎng)特性,將流量調(diào)為Q2,這時(shí)離心泵的特性曲線(H—Q曲線)不變,管網(wǎng)特性曲線由R1變化到R2,與n1時(shí)的離心泵特性曲線相交于M3,此時(shí)離心泵為Q2,壓力為Hf,在曲線上看出,Hf>H1,雖然流量下降了,但是壓力卻上升了,其消耗的軸功率為
●用速度調(diào)節(jié)流量時(shí)壓力的變化
H2 = H1( n / n0 )2( ρ / ρ0 )
●用檔板調(diào)節(jié)流量時(shí)壓力的變化
Hf > H1
●檔板調(diào)節(jié)與轉(zhuǎn)速調(diào)節(jié)消耗軸功率的差值:
由于在運(yùn)行時(shí),用轉(zhuǎn)速調(diào)節(jié)流量時(shí), H2 << H1,在工程計(jì)算中定義:
Hf ≈ H1
檔板調(diào)節(jié)與轉(zhuǎn)速調(diào)節(jié)消耗軸功率的差值:
將 H2 = H1( n / n0 )2( ρ / ρ0 )與Hf ≈ H1 代入上式可得:
△ P ≈ P3 [1 - ( n / n0 )2( ρ / ρ0 )]
從而得出用轉(zhuǎn)速調(diào)節(jié)流量比用檔板調(diào)節(jié)流量要節(jié)約按轉(zhuǎn)速變化的平方系數(shù)的能量。
1、 高壓變頻器的工作原理:
(1)高壓變頻器的構(gòu)成:
多電平單元串聯(lián)高壓變頻器是由十八個(gè)相同的單元模塊構(gòu)成,每六個(gè)模塊為一組,分別對(duì)應(yīng)高壓回路的三相,單元供電由移相變壓器進(jìn)行供電,原理圖如下:
圖6 高壓變頻器內(nèi)部結(jié)構(gòu)圖
(2)功率單元構(gòu)成:
功率單元是一種單相橋式變換器,由輸入切分變壓器的副邊繞組供電。經(jīng)整流、濾波后由4個(gè)IGBT以PWM方法進(jìn)行控制,產(chǎn)生設(shè)定的頻率波形。變頻器中所有的功率單元,電路的拓?fù)浣Y(jié)構(gòu)相同,實(shí)行模塊化的設(shè)計(jì)。其控制通過光纖發(fā)送。原理框圖如下所示:
圖7 功率單元原理框圖
來自主控制器的控制光信號(hào),經(jīng)光/電轉(zhuǎn)換,送到控制信號(hào)處理器,由控制電路處理器接收到相應(yīng)的指令后,發(fā)出相應(yīng)設(shè)的IGBT的驅(qū)動(dòng)信號(hào),驅(qū)動(dòng)電路接到相應(yīng)的驅(qū)動(dòng)信號(hào)后,發(fā)出相應(yīng)的驅(qū)動(dòng)電壓送到IGBT控制極,操作IGBT關(guān)斷和開通,輸出相應(yīng)波形。
功率單元中的狀態(tài)信息將被收集到應(yīng)答信號(hào)電路中進(jìn)行處理,集中后經(jīng)電/光轉(zhuǎn)換器變換,以光信號(hào)向主控制器發(fā)送。
(3)、高壓變頻器運(yùn)行原理:
高壓變頻器的每個(gè)功率單元相當(dāng)于一個(gè)三電平的二相輸出的低壓變頻器,通過疊加成為高壓三相交流電,以6KV變頻器為例,論述:6KV輸出電壓的變頻器,每相有6個(gè)功率單元相串聯(lián)。單元的輸入電壓為三相600V,輸出則為單相577V,單元相互串聯(lián)疊加后可輸出相電壓3464V。當(dāng)變頻器輸出頻率為50HZ時(shí),相電壓為13階梯波,如下圖所示。圖中UA1 … UA6分別為A相6個(gè)功率單元的輸出電壓,疊加后為變頻器A相輸出電壓UA0。圖中顯示出了生成PWM控制信號(hào)時(shí)所采用A相參考電壓UAr,可以看出UA0很好地逼近UAr。UAF為A相輸出電壓中的基波成分。
圖8 相電壓回路疊加波形
由于變頻器中點(diǎn)與電動(dòng)機(jī)中性點(diǎn)不連接,變頻器輸出實(shí)際上為線電壓,由A相和B相輸出電壓產(chǎn)生的UAB輸出線電壓可達(dá)6000V,為25階梯波。如下圖所示,為輸出的線電壓和相電壓的階梯波形,UAB不僅具有正弦波形而且臺(tái)階數(shù)也成倍增加,因而諧波成分及dV/dt均較小。
圖9 線電回路疊加波形
(4)、多電平單元串聯(lián)疊加型變頻器的三相波形輸出質(zhì)量:
高壓變頻器在運(yùn)行后,將輸入的工頻的三相高壓交流電轉(zhuǎn)化為可以進(jìn)行頻率可調(diào)節(jié)的三相交流電,其電壓和頻率按照V/F的設(shè)定進(jìn)行相應(yīng)的調(diào)節(jié),保持電機(jī)在不同的頻率下運(yùn)行,而定子磁心中的主磁通保持在額定水準(zhǔn),提高電機(jī)的轉(zhuǎn)換效率,在下圖中是在現(xiàn)場(chǎng)運(yùn)行時(shí),經(jīng)過PT采集的電動(dòng)機(jī)三相輸入波形:
圖5 電動(dòng)機(jī)入電壓波形
多重疊加應(yīng)用,高壓變頻器輸出電壓的諧波含量很低,已達(dá)到常規(guī)供電電壓允許的諧波含量,同時(shí)輸出電壓的dV/dt較小,不會(huì)增加電機(jī)繞組的應(yīng)力,可以向普通標(biāo)準(zhǔn)型交流電動(dòng)機(jī)供電,不需要降容或加輸出濾波電抗器,保證了高壓設(shè)備的通用性。
1、 高壓變頻器在3號(hào)泵上的應(yīng)用與效果:
(1)、高變頻器安裝運(yùn)行:
燕化公司動(dòng)力事業(yè)部一供水車間3號(hào)水泵原來采用工頻運(yùn)行,閥門調(diào)節(jié)方式控制流量,不能滿足生產(chǎn)工藝要求,又浪費(fèi)了大量的電能。為此北京市水務(wù)局于2004年12月份投資采用哈爾濱九洲電氣股份有限公司生產(chǎn)的高壓變頻調(diào)速裝置對(duì)3號(hào)泵進(jìn)行改造。該裝置采用單元串聯(lián)式多重疊加型直接高—高變頻器,帶自動(dòng)旁路柜,就地,遠(yuǎn)控均為彩色液晶觸摸屏控制,預(yù)留DCS控制和閉環(huán)控制功能。并于2005年1月4日正式投入運(yùn)行。經(jīng)過半年的餓考核,哈爾濱九洲電氣股份有限公司所生產(chǎn)的高壓變頻調(diào)速裝置運(yùn)行穩(wěn)定,性能良好,即滿足了生產(chǎn)工藝的要求,又具有顯著的節(jié)能效果。
(2)、現(xiàn)場(chǎng)設(shè)備參數(shù):
●名稱:離心式清水泵 型號(hào):24SA—10A
揚(yáng)程:39m 流量:2700 m3/h
允許吸上真空高度:4.8 m 轉(zhuǎn)速:730 r/min
功率:319KW 配用功率:360KW
生產(chǎn)日期:1975年5月 重量:4100Kg
生產(chǎn)廠家:長沙水泵廠
●名稱:異步電動(dòng)機(jī) 型號(hào):JS158-8
額定功率:380KW 額定電壓:6000V
額定電流:47A 環(huán)境溫度:35℃
轉(zhuǎn)速:740 r/min 絕緣等級(jí):A
接法:星 重量:4100 Kg
技術(shù)條件:OAG.510.004 序號(hào):750259
生產(chǎn)日期:1975年6月
生產(chǎn)廠家:湘潭電機(jī)廠
●名稱:高壓大功率變頻調(diào)速裝置
型號(hào):JZHICON-IA-06/50 額定輸入電壓:6000V
額定輸出電壓:6000V 額定輸出頻率:50HZ
額定輸出功率:500KW 額定輸出電流:50A
輸出頻率調(diào)節(jié)范圍:0~50 HZ
生產(chǎn)廠家:哈爾濱九洲電氣股份有限公司
(3)、電動(dòng)機(jī)工頻運(yùn)行時(shí)的工況:
電動(dòng)機(jī)電流:26A 電動(dòng)機(jī)溫度:45℃
運(yùn)行頻率:50HZ 出口壓力:0.50Mpa
輸出流量:880 m3/h 出口閥擋板開度:60%
(4)、電動(dòng)機(jī)變頻調(diào)速運(yùn)行時(shí)的工況:
電動(dòng)機(jī)電流:14A 電動(dòng)機(jī)溫度:25℃
運(yùn)行頻率:39.8HZ 出口壓力:0.33Mpa
輸出流量:880 m3/h 出口閥擋板開度:100%
(5)、電動(dòng)機(jī)工頻運(yùn)行時(shí)的耗電量:
每小時(shí)耗電:(26A÷47A)×380KW×1h = 210KW
每天耗電:210×24h = 5040 kwh
每年耗電:5040 × 365 = 1839600 kwh
(6).電動(dòng)機(jī)變頻運(yùn)行時(shí)的耗電量:
每小時(shí)耗電:(26A÷47A)×380KW×1h = 113.2 kwh
每天耗電:113.2×24h = 2716.8 kwh
每年耗電:2716.8×365 = 991632 kwh
(7).電動(dòng)機(jī)采用高壓變頻調(diào)速裝置后的電量:
每小時(shí)節(jié)電:210 - 113.2 = 96.8 kwh
每天節(jié)電:5040 - 2716.8 = 2323.2 kwh
每年節(jié)電:1839600 - 991632 = 847968 kwh
(8).平均節(jié)電率:
847968 ÷ 1839600 = 46%
(9).電動(dòng)機(jī)采用高壓變頻調(diào)速裝置后節(jié)約電費(fèi):
平均電費(fèi)以0.5元/ kwh計(jì)算:
每年節(jié)約電費(fèi):847968 kwh × 0.5元/kwh = 423984 元
≈42.4萬元
6、結(jié)束語:
通過北京燕化公司動(dòng)力事業(yè)部一供水車間的3號(hào)泵高壓變頻器調(diào)速改造,解決了大容量的離心泵在供水量與用戶量相值相近的小水量輸出情況的安全運(yùn)行的難題。使3號(hào)泵安全地運(yùn)行于額定流量的1/3以下,并可以保持精確的流量調(diào)節(jié),在不抽干小流量地表水的同時(shí),保證的用戶終端的用水需求。
高壓變頻器的精確控制功能,可以使水泵工作于原來調(diào)節(jié)方式下無法達(dá)到的工況,在極小流量的情況下仍能精細(xì)的調(diào)節(jié)介質(zhì)流量,這樣就能將大泵使用一些原先無法應(yīng)用的小流量水源,這樣在節(jié)約大量電量的同時(shí),同時(shí)充分利用了稀少的水資源。
在自主創(chuàng)新,占領(lǐng)世界科技高端的精神帶動(dòng)下,具有自主知識(shí)產(chǎn)權(quán)的國產(chǎn)大功率與超大功率高壓變頻的技術(shù)不斷成熟,在中國的大型工業(yè)領(lǐng)域內(nèi)的電動(dòng)機(jī)調(diào)速應(yīng)用越來廣泛,并開始進(jìn)入原來由國外的高壓變頻器壟斷的領(lǐng)域。使高壓變頻器這種現(xiàn)代電力電子的高科技產(chǎn)品將在我國能源高效利用的領(lǐng)域得到更加廣泛的應(yīng)用。
標(biāo)簽:
中國傳動(dòng)網(wǎng)版權(quán)與免責(zé)聲明:凡本網(wǎng)注明[來源:中國傳動(dòng)網(wǎng)]的所有文字、圖片、音視和視頻文件,版權(quán)均為中國傳動(dòng)網(wǎng)(m.u63ivq3.com)獨(dú)家所有。如需轉(zhuǎn)載請(qǐng)與0755-82949061聯(lián)系。任何媒體、網(wǎng)站或個(gè)人轉(zhuǎn)載使用時(shí)須注明來源“中國傳動(dòng)網(wǎng)”,違反者本網(wǎng)將追究其法律責(zé)任。
本網(wǎng)轉(zhuǎn)載并注明其他來源的稿件,均來自互聯(lián)網(wǎng)或業(yè)內(nèi)投稿人士,版權(quán)屬于原版權(quán)人。轉(zhuǎn)載請(qǐng)保留稿件來源及作者,禁止擅自篡改,違者自負(fù)版權(quán)法律責(zé)任。
產(chǎn)品新聞
更多>以簡驅(qū)繁,精準(zhǔn)智控 | 維智S1系列新一代...
2024-11-01
新品發(fā)布:CD300系列總線型伺服驅(qū)動(dòng)器
2024-10-31
2024-10-31
2024-10-31
新勢(shì)能 新期待|維智B1L直線伺服驅(qū)動(dòng)器
2024-10-31
2024-10-29
推薦專題
更多>